AS 1657 explained for WA sites

AS 1657:2018 is the Australian Standard for fixed platforms, walkways, stairways and ladders. Here's what it covers, what it asks for in plain words, how inspection intervals are set, and how it sits next to the standard for roof anchors.

Standard
AS 1657:2018
Covers
Fixed platforms, walkways, stairs and ladders
Used by
Staff and contractors, not the public
Interval
Agreed per item, not one fixed figure

The short version

  • AS 1657 sets out how fixed platforms, walkways, stairways and ladders are designed, built and installed.
  • It covers access for people who operate, inspect, maintain or service plant and buildings. It isn't the standard for public stairs.
  • It prefers walkways and stairs over ladders. A ladder is for places where a stair isn't practical.
  • Where someone could fall from an edge, it calls for guardrail, usually with a toeboard. Taller rung ladders need a cage or a ladder fall-arrest system.
  • It doesn't set one fixed inspection interval. That depends on the manufacturer, how much the item is used and its environment.
  • Roof anchors and static lines are a different standard, AS/NZS 1891.4:2025, on a 12-month cycle.

What AS 1657 covers

AS 1657 (often written AS1657) is the standard for permanent access built into a site or building. Think of the platform beside a machine, the walkway across a roof, the stair up to a plant deck and the ladder to a roof hatch. The 2018 edition replaced the 1992 one and is the current version.

It's written for access used by operators, inspectors, maintenance crews and service contractors. Public stairs, ramps and balustrades are covered by the National Construction Code and its own standards. Portable ladders, scaffolding and temporary edge protection have their own standards too.

  • Roof access ladders and roof hatches
  • Roof walkways and plant decks
  • Stairs to mezzanines, plant rooms and tanks
  • Machine and conveyor access platforms
  • Fixed ladders on tanks, silos and structures
  • Crossover stairs over pipes and conveyors
  • Guardrail along platform and walkway edges
  • Gates and openings at the top of ladders
In plain words

The main requirements

A general summary, not the standard itself. Designers and fabricators work from the full document, which sets the dimensions, loads and tests.

The right type of access

The standard sets an order of preference: walkways first, then stairs, then step-type ladders, then rung-type ladders. The steeper the access, the higher the risk. If people carry tools or parts up and down often, a stair is usually the answer.

Ladder types

A step-type ladder has flat treads and handrails, and sits steeper than a stair. It suits regular trips to a plant platform or mezzanine where a stair won't fit. A rung-type ladder has rungs between two stiles and runs near vertical. It's for roofs, tanks and structures with no room for anything else. Single rungs fixed into a wall or pit are the last resort.

Cages, fall arrest and landings

Taller rung ladders need protection against a fall: a ladder cage, or a ladder fall-arrest system the climber clips onto. Long climbs are broken up with landings. At the top, the stiles carry on above the landing so you have something to hold as you step off, and the opening in the guardrail has a gate.

Guardrail and toeboards

Where someone could fall from a platform, walkway or landing, the standard calls for guardrail: a top rail at about waist height, a middle rail and a toeboard. The toeboard stops tools, bolts and boots sliding off onto people below. Guardrail has to hold a real load, so loose posts and rusted bases matter.

Stairs

Every step in a flight has the same rise and going, so nobody misjudges a step. Treads are slip-resistant. Handrails run the length of the flight, on both sides of wider stairs, and long flights get a landing part way up.

Walkways and platforms

A slip-resistant surface, enough width to walk without turning sideways, and enough headroom. Sloping walkways get cleats or a grip surface. Grating is clipped down so it can't lift or shift, and the structure is sized for the people, tools and parts that will be on it.

Inspection

How often should AS 1657 items be inspected?

AS 1657 doesn't set one fixed inspection interval. The right interval for each item depends on three things:

  • The manufacturer. Follow the manufacturer's or designer's instructions where they exist.
  • How much it's used. A stair climbed every shift wears faster than a roof ladder used twice a year.
  • Its environment. Salt air on the coast, chemicals or washdown in a plant, and heat and dust on a mine site all speed up wear and corrosion.

So we agree an interval with you for each item, or each group of similar items, and record it in the register. You get a reminder before each one falls due. If the way an item is used changes, we change its interval.

WA's work health and safety laws ask duty holders to manage fall risks so far as is reasonably practicable. A dated record of each check is a simple way to show how you're doing that. Who is responsible in WA?

Two standards

AS 1657 and AS/NZS 1891.4: what's the difference?

Most roofs have both: a ladder or hatch to get up, and anchors or a static line once you're there. They're covered by different standards and run on different cycles.

AS 1657:2018AS/NZS 1891.4:2025
CoversFixed platforms, walkways, stairs, ladders and guardrailRoof anchors, static lines, rails and other installed fall-arrest systems
How it keeps people safeStops a fall happening in the first placeCatches a fall once it happens
Inspection intervalNot one fixed figure. Set by the manufacturer, use and environmentEvery 12 months
In our registerEach item on its own agreed intervalEach anchor and line on a 12-month cycle
What we inspect

The structure, the fixings and the way people use it

  • Stiles, rungs, treads and stringers
  • Cages, landings, gates and step-off points
  • Guardrail, handrails, mid-rails and toeboards
  • Walkway and platform grating, clips and supports
  • Fixings, welds, corrosion and cracking
  • Roof hatches: hinges, stays and latches
  • Slip resistance and worn surfaces
  • Signage and the safe way on and off

Repairs and fabrication in our own shop

Failed items are tagged out of service on the day, and your site contact is told before we leave. We're trade-qualified boilermakers with our own fabrication shop, so we make and fit most repairs ourselves. That covers rungs and treads, guardrail and toeboards, gates, cage hoops and brackets, through to full replacement ladders and stairs in aluminium or steel. If a ladder no longer suits how it's used, we can replace it with a stair or platform.

Ladder, stair and walkway inspections · Repairs · Access platforms

The register

A QR tag on every item, and a record you can open

A tag on every item

Numbered, QR-coded and stamped with each inspection date. Anyone can check it at a glance, or scan it to open the record.

Photos and results

Each item photographed as found and as left, with a result against every check.

Its own interval

The interval we agree for each item is recorded against it, with a reminder before the next one is due.

A register login

See the history and download certificates whenever an auditor, insurer or client asks.

Checklist

What to do now

  1. List your fixed access

    Every ladder, stair, walkway, platform and hatch on the site or roof.

  2. Find the last inspection

    Check the tags and old reports. No record means a baseline inspection is the place to start.

  3. Look at how each item is used

    Daily use, coastal air or chemicals point to a shorter interval.

  4. Book an inspection

    Every item tagged, photographed and recorded, and failed items taken out of service.

  5. Set the intervals

    Agreed per item and kept in the register, with a reminder before each one is due.

Questions

Common questions

Is AS 1657 law in WA?

Not by itself. Australian Standards aren't Acts of Parliament. WA's work health and safety laws ask duty holders to manage fall risks so far as is reasonably practicable, and AS 1657 is the standard fixed ladders, stairs and platforms are usually measured against.

How often should fixed ladders and walkways be inspected?

AS 1657 doesn't set one fixed interval. It depends on the manufacturer, how much the item is used and its environment. We agree an interval with you for each item and record it in the register.

Does AS 1657 apply to public stairs?

No. It's for access used by staff and contractors to operate, inspect, maintain or service plant and buildings. Public stairs and balustrades are covered by the National Construction Code.

Our roof ladder is older than the 2018 edition. Is that a problem?

Not automatically. A new edition doesn't make every older ladder unusable overnight. But if it's damaged, being modified or no longer suits how it's used, the current edition is the benchmark for the fix. We note anything that falls short and explain the options.

What's the difference between a step-type and a rung-type ladder?

A step-type ladder has flat treads and handrails and sits at a steep angle, a bit like a very steep stair. A rung-type ladder has rungs between two stiles and runs near vertical. Step-type is preferred where there's room.

Can you replace a ladder that fails?

Yes. We fabricate replacements in aluminium or steel in our own shop and install them. Where a stair or platform would suit the job better, we'll say so.

General information, not legal or engineering advice. This page summarises AS 1657:2018 in plain words and doesn't reproduce it. Design and fabrication work should follow the full standard, available from Standards Australia, and the manufacturer's instructions.

Sources: Standards Australia, AS 1657:2018 · WorkSafe WA, falls code of practice · WorkSafe WA, PCBU

Get a quote

Need your ladders, stairs or walkways checked?

Four quick details and we'll call you back with a fixed price.

We call you back within one business day. Rather talk now? Call 0438 499 825